Chapter 9: Troubleshooting
283
Enclosure
Overheat
Overheating is a potentially serious condition because the
excessively high temperatures can lead to disk drive failure and
controller malfunction.
Overheating usually results from:
• Fan failure
• Poor air circulation around the enclosure
Fan Failure
On VessRAID, there are two kinds of fans:
• Power supply fan
• RAID Controller fan
If a power supply fan fails, you must replace the power supply.
If a RAID Controller fan fails, you can replace it onsite. See
page 210.
Air Circulation
Air circulation around the VessRAID enclosure may be a more
complex problem. Use the thermometer icons to help you locate
the specific hot spot. Check for these conditions:
• Accumulated dust or objects blocking the fans
• Less than a minimum of 5 inches (13 cm) space between the
back of the VessRAID and the wall or other object
• Ambient temperature above 95°F (35°C) where the
VessRAID is operating
Cooling Down the Enclosure
To cool down a VessRAID enclosure:
• Correct any problems identified above
• Power down the VessRAID and let it sit for an hour or longer

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Promise Technology VessRAID 1740s and is the answer not in the manual?

Promise Technology VessRAID 1740s Specifications

General IconGeneral
BrandPromise Technology
ModelVessRAID 1740s
CategoryNetwork Storage Server
LanguageEnglish

Related product manuals