EasyManua.ls Logo

Qirod QD100 Series - APPENDIX A: SERIAL COMMUNICATION

Default Icon
163 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
111
Forward/reverse speed
tracking and restart
function (STR function)
is activated.
the inverter restarts.
a-10
In low speed
sleep
See parameter f501.
Disabled This function or raise
the frequency instruction to
f006+f906.
a-11
Key fault on
the keyboard
Certain key on the
keyboard panel is
continuously pressed
more than 20 s or the
panel is damaged.
If all keys are released but the
alarm does not disappear, the
inverter has to be repaired.
a-12
In the
process of
parameter
initialization
See parameter f120.
If the alarm code is
momentarily displayed and
then disappears, the inverter
comes back to normal.
a-13
Loss of
analog signal
Analog input terminal
detection level is lower
than the setting level of
f422.
Check analog input terminal
e1
Exceeding
displayed
digit number
by 1 digit
Displayed digit number
exceeds 4 digits.
Try to reduce the set point of
f422.
eun1
In the
process of
self-setting
Inverter is performing
self-setting.
If the alarm code is
momentarily displayed and
then disappears, the inverter
comes back to normal.
Table 3.3 Display of early warning code
Code Type Description
---c Overcurrent early warning Inverter is in current amplitude limiting

Table of Contents