2: ODD, datum format :< 8, O, 2 >.
NO. Parameter Name Setting Range
Default
f802 Modbus address 0~247 1
NO. Parameter Name Setting Range
Default
f803 Modbus timeout 0~100 0
0: timeout check disabled.
1-100: 1=1s.
NO. Parameter Name Setting Range
Default
f804 Modbus transger waiting time 0~2.00s 0.00
NO. Parameter Name Setting Range
Default
f805 Modbus behavior on communication fault
0~4 4
0: Inverter stop, communication command, frequency mode open(by f002, f003)
1: None (continued operation)
2: Deceleration stop
3: Coast stop
4: Communication error (e-33 trip) or Network error (e-35 trip)
NO. Parameter Name Setting Range
Default
f806 Number of motor poles for communication
1~8 2
NO. Parameter Name Setting Range
Default
f821 Factory reserved
f822 Factory reserved
f823 Factory reserved
f824 Factory reserved
f825 Factory reserved