9–Fibre Channel Interactive Commands
Loopback Test (-kl)
SN0054667-00 C 9-29
Loopback Test (-kl)
4. Adapter Diagnostics2. Fibre Channel Adapter1. Loopback Test
From the FC Diagnostics menu, select the Loopback Test option. From the port
menu, select a port to open the Loopback Test menu with options to view test
parameters, reset test parameters, configure test parameters, and run the
external loopback test. For example:
FC Diagnostics
HBA Model QLE2462 SN: GFC0718P57753
1: Port 1: WWPN: 21-00-00-1B-32-17-F9-C4 Online
2: Port 2: WWPN: 21-01-00-1B-32-37-F9-C4 Loop Down
(p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit)
Please Enter Selection: 1
Loopback Test
=======================================================
HBA : 0 Port: 1
SN : GFC0718P57753
HBA Model : QLE2462
HBA Desc. : QLE2462 PCI Express to 4Gb FC Dual Channel
FW Version :
WWPN : 21-00-00-1B-32-17-F9-C4
WWNN : 20-00-00-1B-32-17-F9-C4
Link : Online
=======================================================
1: Display Test Parameters
2: Reset Test Parameters
3: Configure Test Parameters
4: Start Diagnostics Test