5–Fibre Channel Noninteractive Commands
-kr (Run Read/Write Buffer Test)
5-20 SN0054667-00 C
Run Adapter Diagnostics Read-write Buffer Test
The {(-ex | exclude) <target wwpn>} parameters specify a device that
will be excluded from the read/write buffer test.
The system shows the following information after a read/write buffer test
completes:
Loop ID/status
Data miscompare
Link failure
Loss of sync
Loss of signal
Invalid CRC
Table 5-6 lists the <param name>, <param alias>, and <param value>
options.
Table 5-6. Diagnostics Parameters
Name
<param name>
Alias
<param
alias>
Value
<param value>
Description
DataPattern DP Test pattern in hex for-
mat
a
Customized (00–FF)
Random pattern
CRPAT
b
CJTPAT
c
CSPAT
d
00, 55, 5A, A5, AA, FF (see
Tabl e 5- 7)
Loopback test only
Loopback test only
Loopback test only
DataSize
e
DS 8, 16, 32, 64, 128, 256,
512, 1024, 2048
Actual data transferred dur-
ing any given pass of the
test
TestCount
f
TC 0–65535
0–10,000
Loopback test only
Read/write buffer test only
TestIncrement
g
TI 1–65535
1–10,000
Loopback test only
Read/write buffer test only
OnError OE 0–2 0 = ignore
1 = stop
2 = loop on error

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Qlogic QConvergeConsole CLI 2400 Series and is the answer not in the manual?

Qlogic QConvergeConsole CLI 2400 Series Specifications

General IconGeneral
BrandQlogic
ModelQConvergeConsole CLI 2400 Series
CategorySoftware
LanguageEnglish

Related product manuals