EasyManua.ls Logo

Qlogic QConvergeConsole CLI 2400 Series - Configure Test Parameters (-Kr); Reset Test Parameters; Start Diagnostics Test (-Kr)

Qlogic QConvergeConsole CLI 2400 Series
366 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9–Fibre Channel Interactive Commands
Read Write Buffer Test
9-34 SN0054667-00 C
Reset Test Parameters
2. Read Write Buffer Test<port selection>2. Reset Test Parameters
From the Read Write Buffer Test menu, select the Reset Test Parameters option
to reset the read write buffer test parameters to their default values.
Configure Test Parameters (-kr)
2. Read Write Buffer Test<port selection>3. Configure Test Parameters
From the Read Write Buffer Test menu, select the Configure Test Parameters
option to open the Read Write Buffer Test submenu with options to configure the
data pattern, data size, number of tests, test increment, error handling, and
devices. For detailed information about these parameters, see Table 5-6.
For example:
Loopback Test
=======================================================
HBA : 0 Port: 1
SN : GFC0718P57753
HBA Model : QLE2462
HBA Desc. : QLE2462 PCI Express to 4Gb FC Dual Channel
FW Version :
WWPN : 21-00-00-1B-32-17-F9-C4
WWNN : 20-00-00-1B-32-17-F9-C4
Link : Online
=======================================================
1: Data Patterns
2: Data Size
3: Number Of Test(s)
4: Test Increment(s)
5: Abort On Error
6: Enable/Disable Device(s)
Start Diagnostics Test (-kr)
2. Read Write Buffer Test<port selection>4. Start Diagnostics Test
From the Read Write Buffer Test menu, select the Start Diagnostics Test option
to run the read write buffer test.

Table of Contents

Related product manuals