5–Fibre Channel Noninteractive Commands
-kl (Run Loopback Test)
SN0054667-00 C 5-17
-kl
(Run Loopback Test)
Use the -kl command to perform an external loopback test.
To perform a loopback test using the default parameters, issue the following
command:
# qaucli -pr fc -kl (<hba instance> | <hba wwpn>)
To do an external loopback test with customized parameters, issue the following
command:
# qaucli -pr fc -kl (<hba instance> | <hba wwpn>) [(<param name> |
<param alias>) <param value>]
Where:
hba instance = Adapter number (use -g command to find)
hba wwpn = World wide port name of the adapter
param name = One of the following:
DataPattern
DataSize
TestCount
TestIncrement
OnError
LoopbackType
param alias = One of the following:
DP
DS
TC
TI
OE
LT
param value = Value for selected parameter (see Tab le 5- 6)