EasyManua.ls Logo

QubicaAMF XLi EDGE Series - Page 167

QubicaAMF XLi EDGE Series
260 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
QubicaAMF XLi EDGE Pinspotter
Section 4-6 Page 4.6-18 Rev. Date: 10/2016
4.6.3.8 PROBLEM: 1
st
ball - table comes down on top of an off spot pin,
thus not picking up the pins. Then the sweep cleans off all of
the pins both standing and down. Table comes down, spots
pins, then goes up, sweep goes up, and the strike light goes on.
Figure 4.6-17
Check with continuity
tester. Replace switch if
defective.
Repair wiring.
Off-Spot switch wiring loose,
disconnected or binding
against frame or machine?
YES
START
Off-Spot switch
adjusting screw
turned in too far?
Broken wire at off
spot switch?
Off-Spot switch
open?
Chassis cable
defective?
Defective chassis?
Check with gauge #088-
001-217. Adjust screw
according to gauge.
Repair or
replace.
Repair or replace
chassis cable.
Replace chassis.
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES

Table of Contents