RADWIN2000CPlusUserManual Release3.5.70 C8
PrivateMIBParameters ChapterC
winlink1000OduAdmActualConnect
Mode
1.3.6.1.4.1.4458.1000.1.1.3
6
Integer RO Unitconnectedasparttoptporptmp.
winlink1000OduAdmAES256Suppor
t
1.3.6.1.4.1.4458.1000.1.1.3
7
Integer RO AES256securitysupportindication.
winlink1000OduAdmAES256State 1.3.6.1.4.1.4458.1000.1.1.3
8
Integer RW Enable/DisableAES256securitymodeoverthe
airlink.
winlink1000OduAdmAES256Status 1.3.6.1.4.1.4458.1000.1.1.3
9
Integer RO AES256operatingstatus
winlink1000OduAdmBatterySavingS
hutdownTime
RW BatterySavingShutdownTimeinminutes0till
batteryrunout‐1ifnotsupported.
winlink1000OduAdmWiFiPowerMo
de
RW WIFIunitpowermode.
winlink1000OduAdmShutdownTim
er
RO ShutdownTimerinseconds.
winlink1000OduAdmGPSState RO GPSstate
winlink1000OduAdmTemperatureC RO Thetemperature(Celsius)insidetheBoard.
winlink1000OduSrvMode 1.3.6.1.4.1.4458.1000.1.2.1 Integer RW Systemmode.Theonlyvaluesthatcanbeset
areinstallModeandslaveMode;normalMode
reservedtotheManagerapplicationprovided
withtheproduct.Achangeiseffectiveafter
linkresynchronization.
winlink1000OduSrvBridging 1.3.6.1.4.1.4458.1000.1.2.3 Integer RO BridgingMode.Validvaluesare:disabled(0)
enabled(1).
winlink1000OduSrvRingLinkMode RW Modeofthelinkregardingringtopology.
winlink1000OduSrvRingTopologySu
pported
RO RingTopologyoptionsare:supportednot
supported
winlink1000OduSrvRingVlanIdTable N/A RingVLANIDstable.
winlink1000OduSrvRingVlanIdEntry N/A VLANIDoftheinternalringmessages.Valid
valuesare1to4094.Initialvalueis0meaning
VLANunaware.INDEX{
winlink1000OduSrvRingVlanIdIndex}
winlink1000OduSrvRingVlanIdIndex RO IndexofVLANIDoftheinternalringmessages.
winlink1000OduSrvRingVlanId RW VLANIDoftheinternalringmessages.Valid
valuesare1to4094.Initialvalueis0meaning
VLANunaware.
winlink1000OduSrvRingEthStatus RO RepresentstheEthernetserviceblockingstate
ofaRingslink
winlink1000OduSrvRingMaxAllowe
dTimeFromLastRpm
RW Definestheminimaltime(inms)requiredfor
determinationofringfailure.
winlink1000OduSrvRingWTR RW Definestheminimaltime(inms)requiredfor
ringrecovery .
winlink1000OduSrvQoSMode RW ModeofQoSfeature.
winlink1000OduSrvQoSConfTable N/A QoSconfigurationtable.
winlink1000OduSrvQoSConfEntry N/A QoSconfigurationtable.INDEX{
winlink1000OduSrvQoSConfIndex}
winlink1000OduSrvQoSConfIndex RO IndexofQoSConfiguration.
winlink1000OduSrvConfVlanQGrou
ps
RO FramesclassificationaccordingtoVLANPriority
IDs.
winlink1000OduSrvConfDiffservQGr
oups
RO FramesclassificationaccordingtoDiffserv.
winlink1000OduSrvConfQueMir RW DesiredPrivateMIR.
winlink1000OduSrvConfQueWeight RW QoSqueueu'sweightsinpercent.
winlink1000OduSrvQoSVlanQGroup
sSetStr
RW FramesclassificationaccordingtoVLANIDs
stringforset.
TableC2:PrivateMIBParameters(Sheet3of32)
Name OID Type
Access
Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Radwin 2000 C PLUS and is the answer not in the manual?

Radwin 2000 C PLUS Specifications

General IconGeneral
BrandRadwin
Model2000 C PLUS
CategoryRadio
LanguageEnglish

Related product manuals