RADWIN2000CPlusUserManual Release3.5.70 C9
PrivateMIBParameters ChapterC
winlink1000OduSrvQoSDiffservQGr
oupsSetStr
RW FramesclassificationaccordingtoDiffservIDs
stringforset.
winlink1000OduSrvQoSMaxRTQueP
ercent
RO MaximalpercentforRT&NRTqueues.
winlink1000OduSrvVlanSupport RO ODUEthernetportVLANsupportand
configurationavailabilityindication.1‐ODU
VLANFunctionalityNotSupported2‐ODU
VLANFunctionalitySupported3‐ODUVLAN
FunctionalitySupportedandAvailable
winlink1000OduSrvVlanIngressMod
e
RW ODUEthernetportingressVLANmode.
winlink1000OduSrvVlanEgressMod
e
RW ODUEthernetportegressVLANmode.
winlink1000OduSrvEgressTag RW ODUethernetportegressVLANtag.Right
mostdigitisVlanpriority(07)otherdigits
composeVlanId(24094)
winlink1000OduSrvEgressProviderT
ag
RW ODUethernetportegressProv iderVLANtag.
RightmostdigitisVlanpriority(07)other
digitscomposeVlanId(24094)
winlink1000OduSrvVlanIngressAllo
wedVIDs
RW ODUethernetportVLANIDsthatwillnotbe
filteredoningress.w|w|w|w|w|w|w|w|(
wherew={04094}andw!=1)
winlink1000OduSrvVlanDisable RW DisableVLANfunctionality.Thefollowingvalues
canbeset:3‐DisableODU&IDUVLAN
Configurations.
winlink1000OduServiceVlanProvide
rListTPIDstr
1.3.6.1.4.1.4458.1000.1.2.6.
8
DisplayString RO HoldsthepossibleProviderTPIDs.
winlink1000OduEthernetRemaining
Rate
1.3.6.1.4.1.4458.1000.1.3.1 Integer RO CurrentEthernetbandwidthinbps.
winlink1000OduEthernetIfTable N/A ODUEthernetInterfacetable.
winlink1000OduEthernetIfEntry N/A ODUEthernetInterfacetableentry.INDEX{
winlink1000OduEthernetIfIndex}
winlink1000OduEthernetIfIndex 1.3.6.1.4.1.4458.1000.1.3.2.
1.1
Integer RO ODUEthernetInterfaceIndex.
winlink1000OduEthernetIfAddress 1.3.6.1.4.1.4458.1000.1.3.2.
1.5
DisplayString RO ODUMACaddress.
winlink1000OduEthernetIfAdminSt
atus
1.3.6.1.4.1.4458.1000.1.3.2.
1.6
Integer RW Requiredstateoftheinterface.
winlink1000OduEthernetIfOperStat
us
1.3.6.1.4.1.4458.1000.1.3.2.
1.7
Integer RO Currentoperationalstateoftheinterface.
winlink1000OduEthernetIfFailActio
n
1.3.6.1.4.1.4458.1000.1.3.2.
1.8
Integer RW Failureactionoftheinterface.
winlink1000OduEthernetNumOfPor
ts
1.3.6.1.4.1.4458.1000.1.3.3 Integer RO NumberofODUnetworkinterfaces.
winlink1000OduEthernetGbeSuppo
rted
1.3.6.1.4.1.4458.1000.1.3.4 Integer RO SupportedGigabitEthernetinODU.
winlink1000OduBridgeBasePortTabl
e
N/A ODUBridgePortstable.
winlink1000OduBridgeBasePortEntr
y
N/A ODUBridgePortstableentry.INDEX{
winlink1000OduBridgeBasePortIndex}
winlink1000OduBridgeBasePortInd
ex
RO ODUBridgePortNumber.
winlink1000OduBridgeBaseIfIndex RO IfIndexcorrespondingtoODUBridgeport.
winlink1000OduBridgeTpMode 1.3.6.1.4.1.4458.1000.1.4.4.
101
Integer RW ODUbridgemode.Achangeiseffectiveafter
reset.Validvalues:hubMode(0)bridgeMode
(1).
TableC2:PrivateMIBParameters(Sheet4of32)
Name OID Type
Access
Description

Table of Contents