RADWIN2000CPlusUserManual Release3.5.70 C‐10
PrivateMIBParameters ChapterC
winlink1000OduBridgeTpPortTable N/A ODUTransparentBridgePortstable.
winlink1000OduBridgeTpPortEntry N/A ODUTransparentBridgePortstableentry.
INDEX{winlink1000OduBridgeTpPortIndex}
winlink1000OduBridgeTpPortIndex RO ODUTransparentBridgePortNumber.
winlink1000OduBridgeTpPortInFra
mes
1.3.6.1.4.1.4458.1000.1.4.4.
3.1.3
Counter RO Numberofframesreceivedbythisport.
winlink1000OduBridgeTpPortOutFr
ames
1.3.6.1.4.1.4458.1000.1.4.4.
3.1.4
Counter RO Numberofframestransmittedbythisport.
winlink1000OduBridgeTpPortInByte
s
1.3.6.1.4.1.4458.1000.1.4.4.
3.1.101
Counter RO Numberofbytesreceivedbythisport.
winlink1000OduBridgeTpPortOutBy
tes
1.3.6.1.4.1.4458.1000.1.4.4.
3.1.102
Counter RO Numberofbytestransmittedbythisport.
winlink1000OduBridgeConfigMode 1.3.6.1.4.1.4458.1000.1.4.4.
102
Integer RO ODUbridgeconfigurationmode
winlink1000OduAirFreq 1.3.6.1.4.1.4458.1000.1.5.1 Integer RW InstallationCenterFrequency.Validvaluesare
productdependent.Achangeiseffectiveafter
linkre‐synchronization.
winlink1000OduAirDesiredRate 1.3.6.1.4.1.4458.1000.1.5.2 Integer RW Deprecatedparameteractualbehaviorisread‐
only.RequiredAirRate.ForChannel
Bandwidthof20105MHzdividethevalueby
124respectively.
winlink1000OduAirSSID 1.3.6.1.4.1.4458.1000.1.5.3 DisplayString RW ReservedfortheManagerapplicationprovided
withtheproduct.TheSectorIDinPoint‐To‐
Multi‐Pointsystems.
winlink1000OduAirTxPower 1.3.6.1.4.1.4458.1000.1.5.4 Integer RW RequiredTransmitpowerindBm.Thisisa
nominalvaluewhiletheactualtransmitpower
includesadditionalattenuation.Theminand
maxvaluesareproductspecific.Achangeis
effectiveimmediately.
winlink1000OduAirSesState 1.3.6.1.4.1.4458.1000.1.5.5 Integer RO CurrentLinkState.Thevalueisactive(3)during
normaloperation.
winlink1000OduAirMstrSlv 1.3.6.1.4.1.4458.1000.1.5.6 Integer RO Thisparameterindicatesifthedevicewas
automaticallyselectedintotheradiolinkmaster
orslave.Thevalueisundefinedifthereisno
link.Thevalueisrelevantonlyforpointto
pointsystems.
winlink1000OduAirResync 1.3.6.1.4.1.4458.1000.1.5.8 Integer RW Settingthisparameterto1willcausethelinkto
restartthesynchronizationprocess.
winlink1000OduAirRxPower 1.3.6.1.4.1.4458.1000.1.5.9.
1
Integer RO ReceivedSignal StrengthindBm.Relevantonly
forpointtopointsystems.
winlink1000OduAirTotalFrames 1.3.6.1.4.1.4458.1000.1.5.9.
2
Counter RO Totalnumberofradioframes.
winlink1000OduAirBadFrames 1.3.6.1.4.1.4458.1000.1.5.9.
3
Counter RO TotalnumberofreceivedradioframeswithCRC
error.Thevalueisrelevantonlyforpointto
pointsystems.
winlink1000OduAirCurrentRate 1.3.6.1.4.1.4458.1000.1.5.9.
4
Integer RO Deprecatedparameter.Actualrateoftheair
interfaceinMbps.ForChannelBandwidthof
20105MHzdividethevalueby124
respectively.
winlink1000OduAirCurrentRateIdx 1.3.6.1.4.1.4458.1000.1.5.9.
5
Integer RO Indexofcurrentairrate.
winlink1000OduAirTxPower36 1.3.6.1.4.1.4458.1000.1.5.1
0
Integer RW Deprecatedparameter.Actualbehaviorisread‐
only.
winlink1000OduAirTxPower48 1.3.6.1.4.1.4458.1000.1.5.1
1
Integer RW Deprecatedparameter.Actualbehaviorisread‐
only.
TableC‐2:PrivateMIBParameters(Sheet5of32)
Name OID Type
Access
Description