RADWIN2000CPlusUserManual Release3.5.70 C‐10
PrivateMIBParameters ChapterC
winlink1000OduBridgeTpPortTable N/A ODUTransparentBridgePortstable.
winlink1000OduBridgeTpPortEntry N/A ODUTransparentBridgePortstableentry.
INDEX{winlink1000OduBridgeTpPortIndex}
winlink1000OduBridgeTpPortIndex RO ODUTransparentBridgePortNumber.
winlink1000OduBridgeTpPortInFra
mes
1.3.6.1.4.1.4458.1000.1.4.4.
3.1.3
Counter RO Numberofframesreceivedbythisport.
winlink1000OduBridgeTpPortOutFr
ames
1.3.6.1.4.1.4458.1000.1.4.4.
3.1.4
Counter RO Numberofframestransmittedbythisport.
winlink1000OduBridgeTpPortInByte
s
1.3.6.1.4.1.4458.1000.1.4.4.
3.1.101
Counter RO Numberofbytesreceivedbythisport.
winlink1000OduBridgeTpPortOutBy
tes
1.3.6.1.4.1.4458.1000.1.4.4.
3.1.102
Counter RO Numberofbytestransmittedbythisport.
winlink1000OduBridgeConfigMode 1.3.6.1.4.1.4458.1000.1.4.4.
102
Integer RO ODUbridgeconfigurationmode
winlink1000OduAirFreq 1.3.6.1.4.1.4458.1000.1.5.1 Integer RW InstallationCenterFrequency.Validvaluesare
productdependent.Achangeiseffectiveafter
linkre‐synchronization.
winlink1000OduAirDesiredRate 1.3.6.1.4.1.4458.1000.1.5.2 Integer RW Deprecatedparameteractualbehaviorisread‐
only.RequiredAirRate.ForChannel
Bandwidthof20105MHzdividethevalueby
124respectively.
winlink1000OduAirSSID 1.3.6.1.4.1.4458.1000.1.5.3 DisplayString RW ReservedfortheManagerapplicationprovided
withtheproduct.TheSectorIDinPoint‐To‐
Multi‐Pointsystems.
winlink1000OduAirTxPower 1.3.6.1.4.1.4458.1000.1.5.4 Integer RW RequiredTransmitpowerindBm.Thisisa
nominalvaluewhiletheactualtransmitpower
includesadditionalattenuation.Theminand
maxvaluesareproductspecific.Achangeis
effectiveimmediately.
winlink1000OduAirSesState 1.3.6.1.4.1.4458.1000.1.5.5 Integer RO CurrentLinkState.Thevalueisactive(3)during
normaloperation.
winlink1000OduAirMstrSlv 1.3.6.1.4.1.4458.1000.1.5.6 Integer RO Thisparameterindicatesifthedevicewas
automaticallyselectedintotheradiolinkmaster
orslave.Thevalueisundefinedifthereisno
link.Thevalueisrelevantonlyforpointto
pointsystems.
winlink1000OduAirResync 1.3.6.1.4.1.4458.1000.1.5.8 Integer RW Settingthisparameterto1willcausethelinkto
restartthesynchronizationprocess.
winlink1000OduAirRxPower 1.3.6.1.4.1.4458.1000.1.5.9.
1
Integer RO ReceivedSignal StrengthindBm.Relevantonly
forpointtopointsystems.
winlink1000OduAirTotalFrames 1.3.6.1.4.1.4458.1000.1.5.9.
2
Counter RO Totalnumberofradioframes.
winlink1000OduAirBadFrames 1.3.6.1.4.1.4458.1000.1.5.9.
3
Counter RO TotalnumberofreceivedradioframeswithCRC
error.Thevalueisrelevantonlyforpointto
pointsystems.
winlink1000OduAirCurrentRate 1.3.6.1.4.1.4458.1000.1.5.9.
4
Integer RO Deprecatedparameter.Actualrateoftheair
interfaceinMbps.ForChannelBandwidthof
20105MHzdividethevalueby124
respectively.
winlink1000OduAirCurrentRateIdx 1.3.6.1.4.1.4458.1000.1.5.9.
5
Integer RO Indexofcurrentairrate.
winlink1000OduAirTxPower36 1.3.6.1.4.1.4458.1000.1.5.1
0
Integer RW Deprecatedparameter.Actualbehaviorisread‐
only.
winlink1000OduAirTxPower48 1.3.6.1.4.1.4458.1000.1.5.1
1
Integer RW Deprecatedparameter.Actualbehaviorisread‐
only.
TableC‐2:PrivateMIBParameters(Sheet5of32)
Name OID Type
Access
Description