RADWIN2000CPlusUserManual Release3.5.70 C23
PrivateMIBParameters ChapterC
winlink1000OduPerfMonTdmDayEn
try
N/A ThisisanentryintheDaysTable.INDEX
{ifIndexwinlink1000OduPerfMonTdmDayIdx}
winlink1000OduPerfMonTdmDayId
x
RO ThistableisindexedperDaynumber.Each
intervalisof15minutesandtheoldestis96.
winlink1000OduPerfMonTdmDayAc
tiveSeconds
RO ParameterindicatingwhethertheTDMservice
wasactive.UnderTDMbackuplinkthe
parameterindicateswhetherthebackuplink
wasactive.
winlink1000OduPerfMonTxThresh1 1.3.6.1.4.1.4458.1000.1.6.2
0
Integer RW WhentheTransmitpowerexceedsthis
thresholdaperformancemonitoringTSL1
counterisincremented.
winlink1000OduPerfMonRxThresh1 1.3.6.1.4.1.4458.1000.1.6.2
1
Integer RW WhentheRXpowerexceedsthisthresholda
performancemonitoringRSL1counteris
incremented.
winlink1000OduPerfMonRxThresh2 1.3.6.1.4.1.4458.1000.1.6.2
2
Integer RW WhentheRXpowerexceedsthisthresholda
performancemonitoringRSL2counteris
incremented.
winlink1000OduPerfMonBBERThres
h1
1.3.6.1.4.1.4458.1000.1.6.2
3
Integer RW WhentheBBERexceedsthisthresholda
performancemonitoringBBERcounteris
incremented.Theunitsare1/10ofapercent.
winlink1000OduPerfMonEthCapacit
yThreshKbps
1.3.6.1.4.1.4458.1000.1.6.2
4
Integer RW Whenthecurrentthroughputisbelowthis
thresholdthecorrespondingcounteris
incremented
winlink1000OduPerfMonHighTraffic
ThreshKbps
1.3.6.1.4.1.4458.1000.1.6.2
5
Integer RW Whenthecurren ttrafficisabovethisthreshold
thencorrespondingcounterisincremented.
winlink1000OduAgnGenAddTrapExt 1.3.6.1.4.1.4458.1000.1.7.1.
1
Integer RW If'yes'ischosentheifIndexUnitSeverity
Time_TandAlarmIdfromthe
winlink1000OduAgnCurrAlarmTablewillbe
bindtotheendofeachprivatetrap.
winlink1000OduAgnGenSetMode 1.3.6.1.4.1.4458.1000.1.7.1.
2
Integer RW Thisparameterisreservedtotheelement
managerprovidedwiththeproduct.
winlink1000OduAgnGenLocalConne
ctionMode
RW LocalConnection(Broadcast)Configurat ion
Mode.Optionsare:1‐SNMPReadWrite2‐
SNMPReadOnly .
winlink1000OduAgnNTPCfgTimeSer
verIP
1.3.6.1.4.1.4458.1000.1.7.2.
1
IPAddress RW IPaddressoftheserverfromwhichthecurrent
timeisloaded.
winlink1000OduAgnNTPCfgTimeOff
setFromUTC
1.3.6.1.4.1.4458.1000.1.7.2.
2
Integer RW OffsetfromCoordinatedUniversalTime
(minutes).Possiblevalues:‐1440..1440.
winlink1000OduAgnRealTimeAndD
ate
1.3.6.1.4.1.4458.1000.1.7.2.
3
OctetString RW Thisparameterspecifiestherealtimeanddate
Format'YYYYMMDDHH:MM:SS'
(Hexadecimal).Adatetimespecification:
fieldoctetscontentsrange‐‐‐‐‐‐‐
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐112year
0..6553623month1..12
34day1..3145hour
0..2356minutes0..596
7seconds0..60(use60
forleapsecond)78deciseconds
0..9ForexampleTuesdayMay261992
at1:30:15PMEDTwouldbedisplayedas:
07c8051a0d1e0f00(1992‐5‐26
13:30:15)
winlink1000OduAgnCurrAlarmLastC
hange
1.3.6.1.4.1.4458.1000.1.7.3.
1
Integer RO Thiscounterisinitializedto0afteradevice
resetandisincrementeduponeachchangein
thewinlink1000OduAgnCurrAlarmTable(either
anadditionorremovalofanentry).
TableC2:PrivateMIBParameters(Sheet18of32)
Name OID Type
Access
Description