EasyManuals Logo

Radwin 2000 C PLUS User Manual

Radwin 2000 C PLUS
297 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #257 background imageLoading...
Page #257 background image
RADWIN2000CPlusUserManual Release3.5.70 C24
PrivateMIBParameters ChapterC
winlink1000OduAgnCurrAlarmTable N/A Thistableincludesthecurrentlyactivealarms.
WhenaRAISEDtrapissentanalarmentry
isaddedtothetable.WhenaCLEARtrapissent
theentryisremoved.
winlink1000OduAgnCurrAlarmEntry N/A Entrycontainingthedetailsofacurrently
RAISEDtrap.INDEX{
winlink1000OduAgnCurrAlarmCounter}
winlink1000OduAgnCurrAlarmCoun
ter
RO Arunningcounterofactivealarms.Thecounter
isincrementedforeverynewRAISEDtrap.Itis
clearedafteradevicereset.
winlink1000OduAgnCurrAlarmSeve
rity
RO CurrentAlarmseverity.
winlink1000OduAgnCurrAlarmId RO UniqueAlarmIdentifier(combinesalarmtype
andinterface).ThesameAlarmIdisusedfor
RAISEDandCLEAREDalarms.
winlink1000OduAgnCurrAlarmIfInd
ex
RO InterfaceIndexwherethealarmoccurred.
Alarmsthatarenotassociatedwithaspecific
interfacewillhavethefollowingvalue:65535.
winlink1000OduAgnCurrAlarmUnit RO Unitassociatedwiththealarm.
winlink1000OduAgnCurrAlarmTrapI
D
RO IDoftheraisedtrapthatwassentwhenthis
alarmwasraised.
winlink1000OduAgnCurrAlarmTime
T
RO Timestampofthisalarm.Thisnumberisin
secondsfromMidnightJanuary1st1970.
winlink1000OduAgnCurrAlarmText RO Alarmdisplaytext(sameasthetextinthesent
trap).
winlink1000OduAgnLastEventsNum
ber
1.3.6.1.4.1.4458.1000.1.7.4.
1
Integer RO Thiscounterindicatesthesizeofthe
winlink1000OduAgnLastEventsTable
winlink1000OduAgnLastEventsTable N/A Thistableincludesthelastevents.Whenatrap
issentanevententryisaddedtothe table.
winlink1000OduAgnLastEventsEntr
y
N/A Entrycontainingthedetailsoflasttraps.INDEX
{winlink1000OduAgnLastEventsIndex}
winlink1000OduAgnLast EventsInde
x
1.3.6.1.4.1.4458.1000.1.7.4.
2.1.1
Integer RO Theindexofthetable
winlink1000OduAgnLast EventsSeve
rity
1.3.6.1.4.1.4458.1000.1.7.4.
2.1.2
Integer RO CurrentTrapseverity.
winlink1000OduAgnLastEventsIfInd
ex
1.3.6.1.4.1.4458.1000.1.7.4.
2.1.3
Integer RO InterfaceIndexwheretheeventoccurred.Traps
thatarenotassociatedwithaspecific
interfacewillhavethefollowingvalue:65535.
winlink1000OduAgnLastEventsTime
T
1.3.6.1.4.1.4458.1000.1.7.4.
2.1.4
Integer RO Timestampofthistrap.Thisnumberisin
secondsfromMidnightJanuary1st1970.
winlink1000OduAgnLastEventsText 1.3.6.1.4.1.4458.1000.1.7.4.
2.1.5
DisplayString RO Trapdisplaytext(sameasthetextinthesent
trap).
winlink1000IduAdmProductType RO IDUconfigurationdescription.
winlink1000IduAdmHwRev RO IDUHardwareRevision.
winlink1000IduAdmSwRev RO IDUSoftwareRevision.
winlink1000OduAdmNumOfExterna
lAlarmIn
RO Indicatesthenumberofcurrentlyavailable
ExternalAlarmInputs.
winlink1000OduAdmExternAlarmIn
Table
N/A ThisistheExternalAlarmInputstable.
winlink1000OduAdmExternAlarmIn
Entry
N/A Entrycontainingtheelementsofasingle
ExternalAlarmInput.INDEX{
winlink1000OduAdmExternAlarmInIndex}
winlink1000OduAdmExternAlarmIn
Index
RO ThisvalueindicatestheindexoftheExternal
AlarmInputentry.
TableC2:PrivateMIBParameters(Sheet19of32)
Name OID Type
Access
Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Radwin 2000 C PLUS and is the answer not in the manual?

Radwin 2000 C PLUS Specifications

General IconGeneral
BrandRadwin
Model2000 C PLUS
CategoryRadio
LanguageEnglish

Related product manuals