RADWIN2000CPlusUserManual Release3.5.70 C27
PrivateMIBParameters ChapterC
winlink1000IduSrvAvailServicesRea
son
RO InformationabouttheTDMServiceavailability.
‐NotApplicableiftheserviceisavailable.The
reasonsforTDMServiceunavailability:‐The
availablethroughputisn'tsufficientforService
demands;‐TheIDUHWdoesn'tsupportthe
service;‐ALink Passwordmismatchwas
detected;‐Theexternalpulsetypedetectedis
improperforTDMservices;‐
ASoftware
versionsmismatchwasdetected.‐ASymetric
TDDModeIsObligated.
winlink1000IduSrvEthActive RO RepresentstheEthernetserviceactivationstate.
winlink1000IduSrvEthAvailable RO RepresentstheEthernetserviceavailability
state.
winlink1000IduSrvEthThroughput RO CurrentavailableEthernetservicethroughputin
bps.
winlink1000IduSrvEthMaxInfoRate RW Holdsthemaximumbandwidth(kbps)tobe
allocatedforEthernetservice.Valueofzero
meansthatEthernetserviceworksasbest
effort.Themaximumvalueisproductspecific.
Refertotheusermanual.
winlink1000IduSrvAvailableTrunksT
1
RO AbitmapdescribingtheTDMtrunksthatcanbe
openedunderT1configuration.Thevalues
takeintoaccounttheIDUhardware
configurationtheairrateandtheinstallation
range.
winlink1000IduEthernetIfTable N/A IDUEthernetInterfacetable.
winlink1000IduEthernetIfEntry N/A IDUEthernetInterfacetableentry.INDEX{
winlink1000IduEthernetIfIndex}
winlink1000IduEthernetIfIndex RO IfIndexcorrespondingtothisInterface.
winlink1000IduEthernetIfAddress RO IDUMACaddress.
winlink1000IduEthernetNumOfLan
Ports
RO NumberofLANinterfacesintheIDU.
winlink1000IduEthernetNumOfSfpP
orts
RO ThenumberofSFPinterfacesintheIDU.
winlink1000IduEthernetSfpProperti
es
RO SFPvenforproperties:VendorNamePNand
Revision.
winlink1000IduEthernetGbeSuppor
ted
RO SupportedGigabitEthernetinIDU.
winlink1000IduEthernetOduInError
s
RO Thenumberofinboundpacketsthatcontained
errorspreventingthemfrombeingdeliverable
toahigherlayerprotocol.
winlink1000IduBridgeTpAging RW Timeoutinsecondsforaging.Notethatforthis
parametertobeeffectivetheODUmustbe
configuredtoHUBmode .Achangeiseffective
immediately.
winlink1000IduTdmTxClockAvailStat
es
RO AvailablestatesoftheTDMTransmitClock
Controleachinputstatusisrepresentedbya
bit.Whenthestateisavailablethebitvalueis
1.Whenthestateisunavailablethebitvalue
is0.Theavailablestatesare:bit2=
Transparentbit3=LocalLoopTimedbit
4=
RemoteLoopTimedbit5=LocalInternalbit6
=RemoteInternal
winlink1000IduTdmT xClockDesiredS
tate
RW Requiredsta teoftheTDMTransmitClock
Control.Achangeiseffectiveafterreactivation
oftheTDMservice.
winlink1000IduTdmTxClockActualSt
ate
RO ActualstateoftheTDMTransmitClockControl.
TableC2:PrivateMIBParameters(Sheet22of32)
Name OID Type
Access
Description