RADWIN2000CPlusUserManual Release3.5.70 C‐28
PrivateMIBParameters ChapterC
winlink1000IduTdmMasterClockAva
ilOptions
RO AvailableoptionsoftheTDMMasterClock
Controleachinputstatusisrepresentedbya
bit.Whentheoptionisavailablethebitvalue
is1.Whentheoptionisunavailablethebit
valueis0.Theavailableoptionsare:bit2=
Automaticbit3 =Trunk#1bit4
=Trunk#2bit
5=Trunk#3bit6=Trunk#4Whennooptions
areavailablethereturnedvalueis:1
winlink1000IduTdmMasterClockDes
ired
RW RequiredTDMMasterClock.Achangeis
effectiveafterre‐activationoftheTDMservice.
winlink1000IduTdmMasterClockAct
ual
RO ActualTrunkusedforTDMMasterClock.
winlink1000IduTdmConfigTable N/A IDUTDMLinksConfigurationtable.
winlink1000IduTdmConfigEntry N/A IDUTDMLinksConfigurationtableentry.
INDEX{winlink1000IduTdmConfigIndex}
winlink1000IduTdmConfigIndex RO Tableindex.
winlink1000IduTdmIfIndex RO Linkindexintheinterfacetable.
winlink1000IduTdmLineCoding RW ThisparameterappliestoT1trunksonly.The
parametercontrolsthelinecoding.Settingthe
valuetoeachoftheindicesappliestoall.A
changeiseffectiveafterthenextopenofthe
TDMservice.
winlink1000IduTdmLoopbackConfig RW Loopbackconfigurationtable.Eachofthe
trunkscanbesetNormalLineloopbackor
Reverselineloopback.Achangeiseffective
immediately.
winlink1000IduTdmLineStatus RO Linestatus.
winlink1000IduTdmCurrentTable N/A IDUTDMLinksStatisticstable.
winlink1000IduTdmCurrentEntry N/A IDUTDMLinksStatisticstableentry.INDEX{
winlink1000IduTdmCurrentIndex}
winlink1000IduTdmCurrentIndex RO Tableindex(Sameas
winlink1000IduTdmLineIndex).
winlink1000IduTdmCurrentBlocks RO Numberofcorrectblockstransmittedtothe
line.
winlink1000IduTdmCurrentDrops RO Numberoferrorblockstransmittedtotheline.
winlink1000IduTdmCurrentTxClock RW TDMTransmitClo ck.Achangeiseffectiveafter
re‐activationoftheTDMservice.
winlink1000IduTdmCurrentBlocksHi
gh
RO Highpartofthe64bitscounterCurrentBlocks
winlink1000IduTdmRemoteQual RO Estimatedaverageintervalbetweenerror
secondevents.Thevalidvaluesare1‐2^31
whereavalueof‐1isusedtoindicatean
undefinedstate.
winlink1000IduTdmRemoteQualEva
l
RO Estimatedaverageintervalbetweenerror
secondeventsduringevaluationprocess.The
validvaluesare1‐2^31whereavalueof‐1 is
usedtoindicateanundefinedstate.
winlink1000IduTdmSrvEval RW EvaluatedTDMservicebitmask.Settingthis
parametertovaluethatisbiggerthanthe
activatedTDMservicebitmaskwillexecute
theevaluationprocessfor30seconds.Setting
thisparameterto0willstoptheevaluation
processimmediately.
winlink1000IduTdmBackupAvailabl
eLinks
RO NumberofTDMbackuptrunks.
winlink1000IduTdmBackupTable N/A IDUTDMLinksStatisticstable.
TableC‐2:PrivateMIBParameters(Sheet23of32)
Name OID Type
Access
Description