RADWIN2000CPlusUserManual Release3.5.70 C29
PrivateMIBParameters ChapterC
winlink1000IduTdmBackupEntry N/A IDUTDMLinksStatisticstableentry.INDEX{
winlink1000IduTdmBackupIndex}
winlink1000IduTdmBackupIndex RO Tableindex.
winlink1000IduTdmBackupMode RW TDMbackupmode:EnableorDisablewhere
themainlinkistheairlinkortheexternallink.
Changeswillbeeffectiveimmediatly.
winlink1000IduTdmBackupCurrentA
ctiveLink
RO TDMbackupcurrentactivelink:N/Aairlinkis
activeorexternallinkisactive.
winlink1000IduTdmJitterBufferSize RW TDMJitterBufferSize.Thevaluemustbe
betweentheminimumandthemaximumTDM
JitterBufferSize.Theunitsare0.1x
millisecond.
winlink1000IduTdmJitterBufferDefa
ultSize
RO TDMJitterBufferDefaultSize.Theunitsare0.1
xmillisecond.
winlink1000IduTdmJitterBufferMinS
ize
RO TDMJitterBufferMinimumSize.Theunitsare
0.1xmillisecond.
winlink1000IduTdmJitterBufferMax
Size
RO TDMJitterBufferMaximumSize.Theunitsare
0.1xmillisecond.
winlink1000IduTdmJitterBufferSizeE
val
RW TDMJitterBufferSizeforevaluation.The
valuemustbebetweentheminimumandthe
maximumTDMJitterBufferSize.Theunitsare
0.1xmillisecond.
winlink1000IduTdmType RW TDMType(Thevalueundefinedisreadonly).
winlink1000IduTdmTypeEval RW TDMTypeforevaluation.
winlink1000IduTdmLineStatusStr RO Linestatus.
winlink1000IduTdmHotStandbySup
port
RO IndicatesifHotStandbyissupported.
winlink1000IduTdmDesiredHotStan
dbyMode
RW DesiredHotStandbyMode.
winlink1000IduTdmHotStandbyOpe
rationStatus
RO TheLinkActualStatus.
winlink1000IduTdmBackupLinkConf
iguration
RW Thecurrentconfigurationofthebackuplink.
winlink1000IduTdmLineInterfaceCo
nfiguration
RW TDMLineinterfaceconfiguration.
winlink1000IduTdmLineImpedance
Configuration
RW TDMlineimpedanceconfiguration(standardT1‐
100OhmnonStandardT1‐110Ohm)
ApplicableonlyforT1TDMtype.
winlink1000HbsAirState 1.3.6.1.4.1.4458.1000.3.1.1 Integer RO HoldsthestateoftheHBS.
winlink1000HbsAirOpMode 1.3.6.1.4.1.4458.1000.3.1.2 Integer RW HoldstheoperationmodeoftheHBS.
winlink1000HbsAirAvailTimeSlots 1.3.6.1.4.1.4458.1000.3.1.3 Integer RO Thisparameterholdsthenumberofavailable
timeslots(notinuse)intheairinterface.
winlink1000HbsAirSectorCbwSuppo
rtedStr
1.3.6.1.4.1.4458.1000.3.1.4 DisplayString RO Representsthechannelbandwidthwhichis
supportedbytheHBSandallconnectedHSUs.
winlink1000HbsAirCompressedMon 1.3.6.1.4.1.4458.1000.3.1.5 OctetString RO HoldsHBSmonitordataincompressedformat:
HBSTrafficMonitorInBytes(4)OutBytes(4)
InFrames(4)OutFrame s(4)HBSState(1)HBS
Freq(4)NumberofLinks(2)ECChange
Counter(4)CurrentRatio(2)TotalAirFrames
(4)HBSRxRateinKbps(4)HBSTxRateinKbps
(4)
HBSRxRateinFps(4)HBSTxRateinFps
(4)HBSSetMode(1).
winlink1000HbsAirConfChanges 1.3.6.1.4.1.4458.1000.3.1.6.
1
OctetString RO 16charactersthatrepresent16HSUs.Each
timeaconfigurationisbeenchangedincrement
therelevantcharacter.
TableC2:PrivateMIBParameters(Sheet24of32)
Name OID Type
Access
Description