RADWIN2000CPlusUserManual Release3.5.70 C35
PrivateMIBParameters ChapterC
winlink1000HbsServiceQoSConfDo
wnQueMir
1.3.6.1.4.1.4458.1000.3.3.3.
5.1.5
DisplayString RW PrivateMIRforeachQoSgroupoftheDownlink
direction(4valuesseparatedbycomma).
winlink1000HbsServiceQoSConfDo
wnQueWeight
1.3.6.1.4.1.4458.1000.3.3.3.
5.1.6
DisplayString RW WeightinpercentforeachQoSgroupofthe
Downlinkdirection(4valuesseparatedby
comma).
winlink1000HbsServiceMobi litySup
ported
1.3.6.1.4.1.4458.1000.3.3.4 Integer RO MobilitySupport(1=Notsupported2=
Supported3‐Transportsupported)
winlink1000HbsServiceMaxNumOf
HSUs
1.3.6.1.4.1.4458.1000.3.3.5 Integer RO HoldsthemaximumnumberofregisteredHSUs
intheHBS.
winlink1000HbsPerfMonThreshTabl
e
N/A Holdstheperformancemonitorthresholds
towardsalltheregisteredHSUs.
winlink1000HbsPerfMonThreshEntr
y
N/A HBSperformancemonitorthresholdtableentry.
INDEX{winlink1000HbsPerfMonThreshIndex}
winlink1000HbsPerfMonThreshInde
x
RO HBSperformancemonitorthresholdtable
index.
winlink1000HbsPerfMonTxThresh1 1.3.6.1.4.1.4458.1000.3.4.1.
1.2
Integer RW HBSperformancemonitortransmitpower
threshold.
winlink1000HbsPerfMonRxThresh1 1.3.6.1.4.1.4458.1000.3.4.1.
1.3
Integer RW HBSperformancemonitorreceivepower
threshold1.
winlink1000HbsPerfMonRxThresh2 1.3.6.1.4.1.4458.1000.3.4.1.
1.4
Integer RW HBSperformancemonitorreceivepower
threshold2.
winlink1000HbsPerfMonBBERThres
h1
1.3.6.1.4.1.4458.1000.3.4.1.
1.5
Integer RW HBSperformancemonitorBBERthreshold.
winlink1000HbsPerfMonEstThroug
hputThreshKbps
1.3.6.1.4.1.4458.1000.3.4.1.
1.6
Integer RW HBSperformancemonitorestimated
throughputThreshold.
winlink1000HbsPerfMonHighTraffic
ThreshKbps
1.3.6.1.4.1.4458.1000.3.4.1.
1.7
Integer RW HBSperformancemonitorhightrafficthreshold.
winlink1000HbsPerfMonAirGenCur
rTable
N/A Thistabledefines/keepstheethernetcounters
ofthecurrent15mininterval.
winlink1000HbsPerfMonAirGenCur
rEntry
N/A ThisisanentryintheCurrentIntervalTable.
INDEX{ifIndex}
winlink1000HbsPerfMonAirGenCur
rRxMBytes
1.3.6.1.4.1.4458.1000.3.4.2.
1.1
Gauge RO CurrentRXMegaBytesstartingfromthe
present15minutesperiod.(Representsthe
LANtrafficRXdirectiontowardtheHSU)
winlink1000HbsPerfMonAirGenCur
rTxMBytes
1.3.6.1.4.1.4458.1000.3.4.2.
1.2
Gauge RO CurrentTransmitMegaBytesstartingfromthe
present15minutesperiod.(Representsthe
LANtrafficTXdirectionfromtheHSU)
winlink1000HbsPerfMonAirGenCur
rEthCapacityThreshUnder
1.3.6.1.4.1.4458.1000.3.4.2.
1.3
Gauge RO Thenumberoftimesthroughputwasbelow
thresholdinthepresent15minutesperiod.
Relevantforpointtopointsystems.
winlink1000HbsPerfMonAirGenCur
rHighTrafficThreshExceed
1.3.6.1.4.1.4458.1000.3.4.2.
1.4
Gauge RO Thenumberoftimesactualtrafficwasabove
thresholdinthepresent15minutesperiod.
winlink1000HbsPerfMonAirGenCur
rActiveSeconds
1.3.6.1.4.1.4458.1000.3.4.2.
1.5
Gauge RO ThenumberofsecondsinwhichRPLEthernet
swervicewasnotblockedinthepresent15
minutesperiod.
winlink1000HbsPerfMonAirGenInte
rvalTable
N/A Thistabledefines/keepstheethernetcounters
ofthelastday(inre solutionof15minintervals).
winlink1000HbsPerfMonAirGenInte
rvalEntry
N/A ThisisanentryintheIntervalTable.INDEX
{ifIndex
winlink1000HbsPerfMonAirGenIntervalIdx}
winlink1000HbsPerfMonAirGenInte
rvalIdx
RO Thistableisindexedperintervalnumber.Each
intervalisof15minutesandtheoldestis96.
winlink1000HbsPerfMonAirGenInte
rvalRxMBytes
RO CurrentRXMegaBytesperinterval.
(RepresentstheLANtrafficRXdirectiontoward
theHSU).
TableC2:PrivateMIBParameters(Sheet30of32)
Name OID Type
Access
Description