RADWIN2000CPlusUserManual Release3.5.70 C36
PrivateMIBParameters ChapterC
winlink1000HbsPerfMonAirGenInte
rvalTxMBytes
RO CurrentTransmitMegaBytesperinterval.
(RepresentstheLANtrafficTXdirectionfrom
theHSU)
winlink1000HbsPerfMonAirGenInte
rvalEthCapacityThreshUnder
RO Thenumberoftimesthroughputwasbelow
thresholdintheeachinterval.Relevantfor
pointtopointsystems.
winlink1000HbsPerfMonAirGenInte
rvalHighTrafficThreshExceed
RO Thenumberoftimesactualtrafficwasabove
thresholdintheeachinterval.
winlink1000HbsPerfMonAirGenInte
rvalActiveSeconds
RO ThenumberofsecondsinwhichRPLEthernet
servicewasnotblockedintheeachinterval.
winlink1000HbsPerfMonAirGenDay
Table
N/A Thistabledefines/keepstheethernetcounters
ofthelastmonth(inresolutionofdays).
winlink1000HbsPerfMonAirGenDay
Entry
N/A ThisisanentryintheDaysTable.INDEX
{ifIndexwinlink1000HbsPerfMonAirGenDayIdx
}
winlink1000HbsPerfMonAirGenDay
Idx
RO ThistableisindexedperDaynumber.Each
intervalisof15minutesandtheoldestis96.
winlink1000HbsPerfMonAirGenDay
RxMBytes
RO CurrentRXMegaBytesperday.(Repre sents
theLANtrafficRXdirectiontowardtheHSU)
winlink1000HbsPerfMonAirGenDay
TxMBytes
RO CurrentTransmitMegaBytesperday.
(RepresentstheLANtrafficTXdirectionfrom
theHSU)
winlink1000HbsPerfMonAirGenDay
EthCapacityThreshUnder
RO Thenumberoftimesthroughputwasbelow
thresholdeachday.Relevantforpointtopoint
systems.
winlink1000HbsPerfMonAirGenDay
HighTrafficThreshExceed
RO Thenumberoftimesactualtrafficwasabove
thresholdeachday.
winlink1000HbsPerfMonAirGenDay
ActiveSeconds
RO ThenumberofsecondsinwhichRPLEthernet
servicewasnotblockedeachday.
winlink1000HsuAirState RO HoldsthestateoftheHSU.
winlink1000HsuAirLinkState RO HoldsthestateoftheHSUlink.
winlink1000HsuAirHsuId RO HoldstheHSUIDassentbytheHBS.
winlink1000HsuAirLocalDeregister RW PerformsLocalHSUDeregistrationwhen‐only
whenthelinkisoff.
winlink1000HsuAirRemoteCompres
sedMon
RO HoldsalltheconfigurationdataofTheHBSin
compressedformat.FieldsIncluded:Rss(1
byte)RssBalance(1byte)Est.Tput(4
bytes)InBytesofthewholesector(4bytes)
OutBytesofthewholesector(4bytes)In
Framesofthewholesector(4bytes)Out
Framesof
thewholesector(4bytes)Max
ThroughputDownLink(4bytes)Max
ThroughputUpLink(4bytes)RxRat eInKbpsof
thewholesector(4bytes )TxRateInKbpsof
thewholesector(4bytes)RxRateInFpsofthe
wholesector(4bytes)TxRateInFpsof
the
wholesector(4bytes)PeakThroughputinthe
DLdirectioninKbps(4bytes)PeakThroughput
intheULdirectioninKbps(4bytes)TxRatio(2
bytes)
winlink1000HsuAirRemoteCompres
sedStatic
RO HoldsalltheconfigurationdataoftheHBSina
compressedformat.HelpstheNMStogetinfo
regardingnewUnregisteredlinks.Fields
Included:Location(32bytes)IPaddress(8
bytesinhexa)Subnetmask(8bytesinhexa)
HBSAntennatype(1byte)HBSAgentVersion
(4bytes)HBSName
(32bytes)
TableC2:PrivateMIBParameters(Sheet31of32)
Name OID Type
Access
Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Radwin 2000 C PLUS and is the answer not in the manual?

Radwin 2000 C PLUS Specifications

General IconGeneral
BrandRadwin
Model2000 C PLUS
CategoryRadio
LanguageEnglish

Related product manuals