RADWIN2000CPlusUserManual Release3.5.70 C38
MIBTraps ChapterC
MIBTraps
General
EachODUcanbeconfiguredwithupto10differenttrapdestinations.Whenthelinkis
operational,eachODUsendstrapsoriginatingfrombothSit eAandSiteB.
ThesourceIPaddressofthetrapisthesendingODU.Thetraporiginatorcanbeidentifiedby
thetrapCommunitystringorbythetrapdescriptiontext.
Eachtrapcontainsatrapdescriptionandadditionalrelevantinformationsuchasalarm
severity,interfaceindex,timestampandadditionalparameters.
TrapParameters
TableC3:MIBTraps(Sheet1of8)
Name ID Severity Description
trunkStateChanged 1 normal IndicatesachangeinthestateofoneoftheTDM
trunks.Raisedbybothsidesofthelink.Contains3
parameters:1‐Description:TDMInterface%n‐%x2‐
%n:Isthetrunknumber3‐%x:Isthealarmtypeand
canbeoneofthefollowing:NormalAISLOSLoopback

linkUp 2 normal Indicatesthattheradiolinkisup.Containsasingle
parameterwhichisitsdescription:1‐Description:
RadioLink‐Synconchannel%nGHz.%nIsthechannel
frequencyinGHz.
linkDown 3 critical Indicatesthattheradiolinkisdown.Containsasingle
parameterwhichisitsdescription:1‐Description:
RadioLink‐
OutofSync.Thereasonis:%s.%sIsthe
reason.
detectIDU 4 normal IndicatesthattheIDUwasdetected.Raisedbyboth
sidesofthelink.Containsasingleparameterwhichis
itsdescription:1‐Description:IDUofType%swas
Detected.%sIsthetypeoftheIDU.
disconnectIDU 5 major IndicatesthattheIDU
wasdisconnected.Raisedby
bothsidesofthelink.Containsasingleparameter
whichisitsdescription:1‐Description:IDU
Disconnected.
mismatchIDU 6 major IndicatesamismatchbetweentheIDUs.Raisedbythe
masteronly.Containsasingleparameterwhichisits
description:1‐Description:IDUsMismatch:OneSide
is%sandthe
Otheris%s.%sIsthetypeoftheIDU.
openedServices 7 normal Indicatesthatserviceswereopened.Raisedbythe
masteronly.Contains3parameters:1‐Description:
%n2outof%n1RequestedTDMTrunkshavebeen
Opened2‐%n1:IstherequestednumberofTDM
truncks3‐%n2:Istheactualnumberof
TDMtrunks
thatwereopened
closedServices 8 normal Indicatesthatserviceswereclosed.Raisedbythe
masteronly.Containsasingleparameterwhichisits
description:1‐Description:TDMServicehasbeen
closed.Thereasonis:%s.%sIsthereason.
incompatibleODUs 9 critical IndicatesthattheODUsareincompatible.Containsa
singleparameterwhichis
itsdescription:1‐
Description:IncompatibleODUs.
incompatibleIDUs 10 major IndicatesthattheIDUsareincompatible.Containsa
singleparameterwhichisitsdescription:1‐
Description:IncompatibleIDUs.