RADWIN2000CPlusUserManual Release3.5.70 C39
MIBTraps ChapterC
incompatibleOduIdu 11 major IndicatesthattheODUandIDUareincompatible.
Containsa singleparameterwhichisitsdescription:1‐
Description:TheIDUcouldnotbe loaded.Thereasonis:
%s.%sIstheincompatibilitytype.
probingChannel 12 normal IndicatesthattheODUismonitoringradaractivity.
Containsa singleparameterwhichisitsdescription:1‐
Description:
Monitoringforradaractivityonchannel%n
GHz.%nisthechannelfrequencyinGHz.
radarDetected 13 normal Indicatesthatradaractivitywasdetected.Containsa
singleparameterwhichisitsdescription:1‐
Description:Radaractivitywasdetectedin%son
channel%nGHz.%sIsthesitename.%nIsthe
channel
frequencyinGHz.
transmittingOnChannel 14 normal IndicatesthattheODUistransmittingonchannel.
Containsa singleparameterwhichisitsdescription:1‐
Description:Transmittingonchannel%nGHz.%nIsthe
channelfrequencyinGHz.
scanningChannels 15 normal IndicatesthattheODUisscanningchannels.Containsa
singleparameterwhichisitsdescription:1‐
Description:Channel
scanninginprogress.
incompatiblePartner 16 critical Indicatesthatconfigurationproblemwasdetectedand
thatlinkinstallationisrequiredinordertofixit.
Containsa singleparameterwhichisitsdescription:1‐
Description:Configurationproblemdetected.Link
installationrequired.
timeClockSet 17 normal IndicatesthattheODUtimeclockwasset.Containsa
singleparameterwhichis
itsdescription:1‐
Description:Thetimewassetto:%p.%pIsthedate
andtime.
configurationChanged 18 normal IndicatesthattheODUrecoveredfromanerrorbut
thereareconfigurationchanges.Containstwo
parameters:1‐Description:Configurationchanged.
Errorcodeis:%n.2‐%nnumber.
hssOpStateChangedToINU 19 normal IndicatesthattheHSSoperatingstatewaschanged
to
INUtype.Containsasingleparameterwhichisits
description:1‐Description:HSSoperatingstatewas
changedto:INU.
hssOpStateChangedToHSM 20 normal IndicatesthattheHSSoperatingstatewaschangedto
HSMtype.Containsasingleparameterwhichisits
description:1‐Description:HSSoperatingstatewas
changedto:HSM.
hssOpStateChangedToHSC 21 normal Indicatesthat
theHSSoperatingstatewaschangedto
HSCtype.Containsasingleparameterwhichisits
description:1‐Description:HSSoperatingstatewas
changedto:HSC_DT/HSC_CT.
vlanModeActive 22 normal IndicatestononVLANPCthatafter2minutesthe
systemwillsupportonlyVLANtagonmanagement
interface.Containsasingleparameterwhich
isits
description:1‐Description:VLANModeisactive.Non
VLANtrafficwillbeblockedin2minutes.
spectrumAnalysis 23 normal IndicatesthattheODUisinSpectrumAnalysismode.
Containsa singleparameterwhichisitsdescription:1‐
Description:Spectrumanalysisinprogress.
hbsHsuDeregisteredOffline 24 normal
IndicatesthataHSUwasderegisteredoffline(outof
link)
hbsHsuDeregisteredSuccessfully 25 normal
IndicatesthataHSUwasderegisteredsuccessfully
hbsHsuRegisteredSuccessfully 26 normal
IndicatesthataHSUwasregisteredsuccessfully
hbsHsuRegistrationFailed 27 normal Indicatesthatregistrationhasfailed
hbsHsuVi olatedState 28 normal
Indicates(ontheHBSside)thataHSUisisviolatedstate
TableC3:MIBTraps(Sheet2of8)
Name ID Severity Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Radwin 2000 C PLUS and is the answer not in the manual?

Radwin 2000 C PLUS Specifications

General IconGeneral
BrandRadwin
Model2000 C PLUS
CategoryRadio
LanguageEnglish

Related product manuals