RADWIN5000HPMPUserManual Release3.5.70 108
Example1
Table 102explains thepurposeofeachmeasurement.
Togetabetterideaofwhatishappening,wewillenlargeeachsectionofFigure 104inturn.
Thetoplefthandgraphshowssectorutilization:
Figure105:SectorUtilization‐Example1
Figure 105showstheoverallsectorutilizationasseenbytheHBS.Atanypoint,youcan
mouseoveranyofthegraphstoseethecurrentvalueinalargermoreconvenientformat.
Table102:TrafficstatisticsforeachHSU
Fieldname Unit Explanation
TrafficUL Mbps TrafficloadsenttotheHBS
TrafficDL Mbps TrafficloadreceivedfromtheHBS
SectorRelativeUL Percentage
PercentageofsectorULtimeslotsutilizedfor
transmissiontotheHBS.MaybeoverHSU’sallocationif
thereareunallocatedULtimeslotsavailable.
SectorRelativeDL Percentage
PercentageofsectorDLtimeslotsutilizedforreception
fromtheHBS.MaybeoverHSU’sallocationifthereare
availableULtimeslotsavailable,allocatedornot
HSUBased
RelativeUL
Percentage
PercentageofHSUULtimeslotsutilizedfortransmission
totheHBS.Maybeover100%ifthereareunallocated
ULtimeslotsavailable.
HSUBased
RelativeDL
Percentage
PercentageofHSUDLtimeslotsutilizedforreception
fromtheHBS.Maybeover100%ifthereareavailable
ULtimeslotsavailable,allocatedornot