Key Counter Interface Unit
SM 2-61 D009/D011/D012/D013/D091/D092
Installation
4. Connect the other terminal of the harness to CN214 [3] on the IOB ( x 3).
5. Cut off the part [4] of the rear cover.
6. Connect the harness from the counter device to CN4 on the key counter interface
board and clamp it with three clamps [5].
7. Reassemble the machine.