Bit Switches
D346 108 SM
5
Not used
Do not change the settings.
6
Reconstruction time for the
first line in receive mode
0: 6 s 1: 12 s
When the sending terminal is controlled by a
computer, there may be a delay in receiving page
data after the local machine accepts set-up data
and sends CFR. This is outside the T.30
recommendation. But, if this delay occurs, set this
bit to 1 to give the sending machine more time to
send data.
Refer to error code 0-20.
ITU-T T.30 recommendation: The first line should
come within 5 s of CFR.
7
Not used
Do not change the settings.
G3-2 Switch 0B - Not used (do not change the settings.)
G3-2 Switch 0C - Not used (do not change the settings.)
4.3.7 IP FAX SWITCHES
IP Fax Switch 00 [SP No. 1-111-001]
No. FUNCTION COMMENTS
0
Not used
Do not change this setting.
1
IP Fax Transport
0: TCP, 1: UDP
Selects TCP or UDP protocol for IP-Fax
2
IP Fax single port selection
0: OFF, 1: ON (enable)
Selects single data port.
3
IP Fax double ports (single data
port) selection
0: OFF, 1: ON (enable)
Selects whether IP-Fax uses a double port.
4 IP Fax Gatekeeper Enables/disables the communication via the