Service Call Conditions
SM Appendix 3-23 D009/D011/D012/D013/D091/D092
Appendix:
Service Call
Conditions
SC Tables: SC6xx
610 D
Mechanical counter error: BK
This SC is only for NA models.
The machine detects the mechanical counter error when SP5987-001 is set
to "1".
Disconnected mechanical counter
Defective mechanical counter
620 B
Communication error between IOB and ADF
After the ARDF is detected, the break signal occurs or communication
timeout occurs.
Incorrect installation of ARDF
ARDF defective
IOB board defective
External noise
621 D
Communication timeout error between IOB and finisher or mailbox
A break (low) signal is received from the finisher or the mailbox.
Disconnected cable
Defective IOB
Defective main board in the peripherals