Copy Adjustments
SM 4-103 D009/D011/D012/D013/D091/D092
Replacement
&
Adjustment
1. Place the test chart on the exposure glass and make a copy from one of the feed
stations.
2. Check the magnification ratio. Use SP4-008 (Scanner Sub Scan Magnification) to
adjust if necessary. Specification: ±0.9%.
4.17.4 ADF IMAGE ADJUSTMENT
Registration
1. Make a temporary test chart as shown above using A3/DLT paper.
2. Place the temporary test chart on the ADF and make a copy from one of the feed
stations.
3. Check the registration, and adjust using the following SP modes if necessary.
SP No. Specification
Side-to-side: 1st side SP6-006-1
0.0 mm ±3 mm
Side-to-side: 2nd side SP6-006-2
Leading Edge SP6-006-3 0.0 mm ±5 mm
Leading Edge: 1st side SP6-006-5 0.0 mm ±3 mm
Leading Edge: 2nd side SP6-006-6 0.0 mm ±2.5 mm
Trailing Erase edge: SP6-006-7 0.0 mm ±10.0 mm