System SP Table-3
SM Appendix 4-37 D009/D011/D012/D013/D091/D092
Appendix:
Service
Program
Mode Tables
4.3 SYSTEM SP TABLE-3
4.3.1 SP3-XXX: PROCESS
3001* P Sensor Setting
001
Current
[0 to 43 / 13 / 0.1 mA ]
Allows you to reset the PWM of the ID sensor LED to avoid a service call
error after clearing NVRAM or replacing the NVRAM.
The PWM data is stored by executing SP-3001-2.
002
ID Initialization -
Performs the ID sensor initial setting. ID sensor output for the bare drum
(VSG) is adjusted automatically to 4.0 ±0.2 V.
Press "Execute" to start. Perform this setting after replacing or cleaning the
ID sensor, replacing the drum, or clearing NVRAM.
3045*
Toner End Setting, ON/OFF
DFU
[0 to 1 / 0 / 1] 0=Off, 1=On
3103*
P Sensor Output
Displays the current VSG, VSP, VSDP, and grayscale control.
If the P sensor does not detect the P pattern, "VSP = 5.0 V/VSG = 5.0 V" is
displayed and an SC code is generated.
If the P sensor does not detect the bare area of the drum, "VSP = 0.0
V/VSG =0.0 V" is displayed and an SC code is generated.
001 Vsg
[0 to 5 / 0 / 0.1]
002 Vsp
[0 to 5 / 0 / 0.1]