EasyManua.ls Logo

Ricoh D009 - System Sp Table-3; Sp3-XXX: Process

Ricoh D009
1209 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System SP Table-3
SM Appendix 4-37 D009/D011/D012/D013/D091/D092
Appendix:
Service
Program
Mode Tables
4.3 SYSTEM SP TABLE-3
4.3.1 SP3-XXX: PROCESS
3001* P Sensor Setting
001
Current
[0 to 43 / 13 / 0.1 mA ]
Allows you to reset the PWM of the ID sensor LED to avoid a service call
error after clearing NVRAM or replacing the NVRAM.
The PWM data is stored by executing SP-3001-2.
002
ID Initialization -
Performs the ID sensor initial setting. ID sensor output for the bare drum
(VSG) is adjusted automatically to 4.0 ±0.2 V.
Press "Execute" to start. Perform this setting after replacing or cleaning the
ID sensor, replacing the drum, or clearing NVRAM.
3045*
Toner End Setting, ON/OFF
DFU
[0 to 1 / 0 / 1] 0=Off, 1=On
3103*
P Sensor Output
Displays the current VSG, VSP, VSDP, and grayscale control.
If the P sensor does not detect the P pattern, "VSP = 5.0 V/VSG = 5.0 V" is
displayed and an SC code is generated.
If the P sensor does not detect the bare area of the drum, "VSP = 0.0
V/VSG =0.0 V" is displayed and an SC code is generated.
001 Vsg
[0 to 5 / 0 / 0.1]
002 Vsp
[0 to 5 / 0 / 0.1]

Table of Contents