Service Call Conditions
D009/D011/D012/D013/D091/D092 3-6 SM Appendix
D
-004: VERSION error
The serial communication does not
work.
Defective SBU
Defective detection circuit on the
BICU
Defective harness
145 C
Scanner adjustment error (B/W Scanner model only)
During the SBU adjustment, the machine detects that the white level read
from the white plate or paper is out of range. (SP4015)
Exposure lamp defective
Dirty white plate
Incorrect position or width of white plate scanning (SP4015)
BICU board defective
SBU board defective
161 D
BICU error
The error result of self-diagnostic by the ASIC on the BICU is detected.
Defective BICU
Defective connection between BICU and SBU
165 D
Copy Data Security Unit error
The copy data security board is not detected when the copy data security
function is set "ON" with the initial setting.
A device check error occurs when the copy data security function is set to
"ON" with the initial setting.
Incorrect installation of the copy data security board
Defective copy data security board