Service Call Conditions
SM Appendix 3-31 D009/D011/D012/D013/D091/D092
Appendix:
Service Call
Conditions
723 B
Stack feed-out motor error
 The stack feed-out HP sensor does not detect the home position of the
stack feed-out belt 3000ms after the stack feed-out belt has moved to its
home position.
 The stack feed-out HP sensor does not turn off 200 ms after the stack
feed-out belt has moved from its home position.
The 1st detection failure causes a jam error, and the 2nd failure causes this
SC code.
 Defective stack feed-out HP sensor
 Overload on the stack feed-out motor
 Defective stack feed-out motor
 Defective main board
 Disconnected or defective harness
725 B
Finisher exit guide plate motor error
After moving away from the guide plate position sensor, the exit guide is not
detected at the home position within the prescribed time.
The 1st detection failure issues a jam error, and the 2nd failure issues this
SC code.
 Guide plate motor disconnected, defective
 Guide plate motor overloaded due to obstruction
 Guide plate position sensor disconnected, defective