System SP Table-1
D009/D011/D012/D013/D091/D092 4-16 SM Appendix
020 Waiting Time: Low: Thin after the time specified with these SPs
has passed.
021 Waiting Time: Medium: Plain
022 Waiting Time: Medium: M-Thick
023 Waiting Time: Medium: Thick 1
024 Waiting Time: Medium: Thick 2
025 Waiting Time: Medium: Thin
026 Temp.: Low: Plain
Adjusts the threshold temperature of
the fusing unit to enter the CPM down
mode.
[100 to 200 / 120 / 1 deg]
If the temperature of the fusing unit is
less than the temperature specified
with these SPs, the machine changes
the CPM (adjustable with SP1916-36
to -45).
027 Temp.: Low: Plain
028 Temp.: Low: Thick 1
029 Temp.: Low: Thick 2
030 Temp.: Low: Thin
031 Temp.: Medium: Plain
032 Temp.: Medium: M-Thick
033 Temp.: Medium: Thick 1
034 Temp.: Medium: Thick 2
035 Temp.: Medium: Thin
036 CPM: Low: Plain
Adjusts the CPM in the CPM down
mode.
C1b/C1.5b: [20 to 35 / 35 / 5 cpm]
C1c/C1.5c: [20 to 45 / 45 / 5 cpm]
037 CPM: Low: M-Thick
Adjusts the CPM in the CPM down
mode.
C1b/C1.5b: [20 to 35 / 35 / 5 cpm]
C1c/C1.5c: [20 to 45 / 45 / 5 cpm]