System SP Table-1
D009/D011/D012/D013/D091/D092 4-18 SM Appendix
1930 OnOff Time Adjust
001
On Time Adjust
[0 to 100 / 40 / 10 msec]
Adjusts the Off-On interval of the transfer belt contact motor. ("On" means
that the transfer belt is in contact with the drum.)
002
Off Time Adjust
[0 to 100 / 20 / 10 msec]
Adjusts the On-Off interval of the transfer belt contact motor. ("Off" means
that the transfer belt is away from the drum.)
1950
Tray Lock at Jam
[0 or 1 / 0 / 1 ] 0= OFF, 1= ON
Not used