System SP Table-5
SM Appendix 4-91 D009/D011/D012/D013/D091/D092
Appendix:
Service
Program
Mode Tables
5411* LDAP Certification
004 Easy Certification
Turns simple authentication on or off for LDAP.
[0 to 1 / 1 / 1]
0: OFF
1: ON
005
Password Null
Not Permit
This SP is enabled only when SP5411-4 is set to "1"
(ON).
[0 to 1 / 0 / 1]
0: Password null is not permitted.
1: Password null is permitted.
5413 Lock Setting
001
Lockout On/Off
[0 to 1 / 0 / 1] 0: OFF, 1:ON
Turns on or off the account lock for the local address book account.
002
Lockout Threshold
[1 to 10 / 5 / 1]
Sets the maximum trial times for accessing the address book account.
003
Cancellation On/Off
[0 to 1 / 0 / 1]
0: OFF (Lockout is not cancelled.)
1: ON (Lockout is cancelled if a user ID and
password are correctly entered after the lockout
function has been executed and a specific time has
passed.)
Turns on or off the cancellation function of the account lockout.
004
Cancellation Time
[1 to 9999 / 60 / 1 min]
Sets the interval of the retry for accessing the local address book account
after the lockout function has been executed.
This setting is enabled only if SP5413-3 is set to "1" (ON).
005 Counter Clear Time
Not Used