System Service Mode
SM Appendix 8-411 D023/D025
Appendix
SP Mode
Tables
004 Coefficient: Mid. *ENG
[0 to 3 / 1 / 1 /step] DFU
005 Coefficient: High *ENG
[0 to 3 / 0 / 1 /step] DFU
Stand-by: Threshold:
Upper Limit
*ENG
[0 to 200 / 180 / 1 deg/step]
006
Specifies the threshold temperature of the pressure roller between M (middle)
and H (high). This SP is referred when the input voltage of the IH inverter is
93% or less (adjustable with SP1-916-026).
Stand-by: Threshold:
Lower Limit
*ENG
[0 to 200 / 120 / 1 deg/step]
007
Specifies the threshold temperature of the pressure roller between L (low) and
M (middle). This SP is referred when the input voltage of the IH inverter is 93%
or less (adjustable with SP1-916-026).
Mid. Thick: A3:
Threshold: Upper Limit
*ENG
[0 to 200 / 200 / 1 deg/step]
008
Specifies the threshold temperature of the pressure roller between M (middle)
and H (high). This SP is referred when the paper of 275 mm width or more is
used in the middle thick paper and 205/154 mm/sec line speed mode.
Mid. Thick: A3:
Threshold: Lower Limit
*ENG
[0 to 200 / 190 / 1 deg/step]
009
Specifies the threshold temperature of the pressure roller between L (low) and
M (middle). This SP is referred when the paper of 275 mm width or more is
used in the middle thick paper and 205/154 mm/sec line speed mode.