EasyManua.ls Logo

Ricoh D025 - Page 1437

Ricoh D025
1522 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Bit Switches
D393 96 SM
Communication Switch 01 [SP No. 1-104-002]
No FUNCTION COMMENTS
0
ECM
0: Off 1: On
If this bit is set to 0, ECM is switched off for all
communications.
In addition, V.8 protocol and JBIG compression
are switched off automatically.
1
Not used
Do not change the settings.
2-3
Wrong connection prevention
method
Bit 3: 0, Bit 2: 0 = None
Bit 3: 0, Bit 2: 1 = 8 digit CSI
Bit 3: 1, Bit 2: 0 = 4 digit CSI
Bit 3: 1, Bit 2: 1 = CSI/RTI
(0,1) - The machine will disconnect the line without
sending a fax message, if the last 8 digits of the
received CSI do not match the last 8 digits of the
dialed telephone number. This does not work
when manually dialed.
(1,0) - The same as above, except that only the
last 4 digits are compared.
(1,1) - The machine will disconnect the line without
sending a fax message, if the other end does not
identify itself with an RTI or CSI.
(0,0) - Nothing is checked; transmission will
always go ahead.
This function does not work when dialing
is done from the external telephone.
4-5
Not used
Do not change the setting.
6-7
Maximum printable page
length available
Bit 7: 0 Bit 6: 0 = No limit
Bit 7: 0 Bit 6: 1 = B4 (364 mm)
Bit 7: 1 Bit 6: 0 = A4 (297 mm)
Bit 7: 1 Bit 6: 1 = Not used
The setting determined by these bits is informed to
the transmitting terminal in the pre-message
protocol exchange (in the DIS/NSF frames).
Communication Switch 02 [SP No. 1-104-003]

Table of Contents

Related product manuals