NCU Parameters
SM 137 D393
Fax Option
Type C5000
(D393)
Address Function Unit Remarks
limit (LOW)
680543 Country dial tone detection time
680544
Country dial tone reset time
(LOW)
680545
Country dial tone reset time
(HIGH)
20 ms
If 680543 contains FF,
the machine pauses for
the pause time (680548 /
680549).
680546
Country dial tone continuous tone
time
- -
680547
Country dial tone permissible drop
time
680548 Country dial wait interval (LOW)
680549 Country dial wait interval (HIGH)
20 ms -
68054A
Time between opening or closing
the DO relay and opening the
OHDI relay
1 ms
See Notes 3, 6 and 8.
SP2-103-012
(parameter 11).
68054B Break time for pulse dialing 1 ms
See Note 3.
SP2-103-013
(parameter 12).
68054C Make time for pulse dialing 1 ms
See Note 3.
SP2-103-014
(parameter 13).
68054D
Time between final OHDI relay
closure and DO relay opening or
closing
1 ms
See Notes 3, 6 and 8.
SP2-103-015
(parameter 14).
This parameter is only
valid in Europe.
68054E Minimum pause between dialed
digits (pulse dial mode)
20 ms
See Note 3 and 8.