System Service Mode
SM Appendix 8-7 D023/D025
Appendix
SP Mode
Tables
Pressure Ready Temp *ENG
[0 to 150 / 20 / 1 deg/step]
007
Sets the heating roller offset temperature at the end of the heating roller. This
value is one of the thresholds to determine if the machine is at the heating roller
target temperature during warm-up.
010 Stand-By: Center * ENG
011 Stand-By: End * ENG
[140 to 170 / 155 / 1 deg/step]
Stand-By: Pressure * ENG
[105 to 135 / 120 / 1 deg/step]
012
Sets the pressure roller offset temperature. This value is one of the thresholds
to determine if the machine is at the heating roller target temperature during
warm-up.
013 Panel Off Mode: Center * ENG
[100 to 150 / 130 / 1 deg /step]
014 Panel Off Mode: Ends * ENG
[100 to 150 / 130 / 1 deg /step]
015 Panel Off Mode: Pressure *ENG
[105 to 135 / 120 / 1 deg /step]
016 Low Power: Center *ENG
017 Low Power: Ends *ENG
[30 to 100 / 40 / 1 deg /step]
018 Low Power: Pressure *ENG
[30 to 135 / 80 / 1 deg /step]
019 Off Mode: Center *ENG
020 Off Mode: Ends *ENG
[0 to 180 / 0 / 1 deg /step]
021 Off Mode: Pressure *ENG
[0 to 170 / 0 / 1 deg /step]

Table of Contents