System Service Mode
D023/D025 8-18 SM Appendix
032 Other2: Center Temp >=226 ENG
033 Other2: End Temp >=226 ENG
[-10 to 10 / 0 / 1 deg/step]
034 Other3: Center Temp >=226 ENG [-10 to 10 / 0 / 1 deg/step]
035 Other3: End Temp >=226 ENG [-10 to 10 / 5 / 1 deg/step]
036 Other4: Center Temp >=226 ENG
037 Other4: End Temp >=226 ENG
[-10 to 10 / 0 / 1 deg/step]
1117 [Idling Time After Heater OFF]
After Ready ENG
[0 to 4 / 4 / 1 sec/step] DFU
001
Specifies the idling time without the lamp on after reaching the ready
temperature.
After Job End ENG
[0 to 4 / 0 / 1 sec/step]
002
Specifies the idling time without the lamp on after job end.
This idling prevents the heating roller overheating after job end.
1118 [Curl Temperature Correction]
001 Operation Pattern *ENG
[0 to 3 / 0 / 1]
002 Humidity 1 *ENG
[0 to 100 / 65 / 1 %]
003 Humidity 2 *ENG
[0 to 100 / 80 / 1 %]
004 Pattern 1: MM: Fusing *ENG
[-15 to 0 / -5 / 1 deg]
005 Pattern 1: MM: Pressure *ENG
[0 to 60 / 0 / 1 deg]
006 Pattern 1: HM: Fusing *ENG
[-15 to 0 / -5 / 1 deg]
007 Pattern 1: HM: Pressure *ENG
[0 to 60 / 0 / 1 deg]