System Service Mode
SM Appendix 8-17 D023/D025
Appendix
SP Mode
Tables
Control Time 2: 226– ENG
[0 to 250 / 0 / 1 sec/step]
019
Specifies the start time of the temperature correction that is set with
SP1116-012 and -013.
The temperature correction is added when the time specified with this SP has
passed after feeding the paper.
Control Time 3: –226 ENG
[0 to 250 / 60 / 1 sec/step]
020
Specifies the start time of the temperature correction that is set with
SP1116-014 and -015.
The temperature correction is added when the time specified with this SP has
passed after feeding the paper.
Control Time 4: –226 ENG
[0 to 250 / 0 / 1 sec/step]
021
Specifies the start time of the temperature correction that is set with SP1116-016
and -017.
The temperature correction is added when the time specified with this SP has
passed after feeding the paper.
022 M-Thick 1: Center Temp >=226 ENG
023 M-Thick 1: Ends Temp. >=226 ENG
[-10 to 10 / 0 / 1 deg/step]
024 M-Thick 2: Center Temp >=226 ENG
025 M-Thick 2: Ends Temp. >=226 ENG
[-10 to 10 / 0 / 1 deg/step]
026 M-Thick 3: Center Temp >=226 ENG [-10 to 10 / 0 / 1 deg/step]
027 M-Thick 3: Ends Temp. >=226 ENG [-10 to 10 / 5 / 1 deg/step]
028 M-Thick 4: Center Temp >=226 ENG
029 M-Thick 4: Ends Temp. >=226 ENG
[-10 to 10 / 0 / 1 deg/step]
030 Other1: Center Temp >=226 ENG
031 Other1: End Temp >=226 ENG
[-10 to 10 / 0 / 1 deg/step]