System Service Mode
D023/D025 8-16 SM Appendix
Ends Temp. 2: 226– ENG
[-10 to 10 / 0 / 1 deg/step]
013
Specifies the temperature correction for the heating roller (ends) when the
paper width is 226 mm or more.
The start time of this SP can be adjusted with SP1116-019.
Center Temp. 3: –226 ENG
[-10 to 10 / 5 / 1 deg/step]
014
Specifies the temperature correction for the heating roller (center) when the
paper width is less than 226 mm.
The start time of this SP can be adjusted with SP1116-020.
Ends Temp. 3: –226 ENG
[-10 to 10 / 0 / 1 deg/step]
015
Specifies the temperature correction for the heating roller (ends) when the
paper width is less than 226 mm.
The start time of this SP can be adjusted with SP1116-020.
Center Temp. 4: –226 ENG
[-10 to 10 / 0 / 1 deg/step]
016
Specifies the temperature correction for the heating roller (center) when the
paper width is less than 226 mm.
The start time of this SP can be adjusted with SP1116-021.
Ends Temp. 4: –226 ENG
[-10 to 10 / 0 / 1 deg/step]
017
Specifies the temperature correction for the heating roller (ends) when the
paper width is less than 226 mm.
The start time of this SP can be adjusted with SP1116-021.
Control Time 1: 226– ENG
[0 to 250 / 60 / 1 sec/step]
018
Specifies the start time of the temperature correction that is set with
SP1116-010 and -011.
The temperature correction is added when the time specified with this SP has
passed after feeding the paper.