System Service Mode
D023/D025 8-32 SM Appendix
[Charge AC Current: HH] Charge Roller AC Current Adjustment for HH
(Color)
2011
Displays/sets the AC current target of the charge roller for HH environment
(High temperature and High humidity). DFU
001 Environmental Target: Bk *ENG
002 Environmental Target: M *ENG
003 Environmental Target: C *ENG
004 Environmental Target: Y *ENG
[0 to 3000 / 1180 / 10 ųA/step]
2012 [Charge Output Control]
001 AC Voltage *ENG
Selects the AC voltage control type.
[0 or 1 / 0 / 1 /step]
0: Process control
1: Manual control (AC voltages are
decided with SP2006.)
2013 [Environmental Correction: PCU]
001
Current Environmental:
Display
*ENG
Displays the environmental condition,
which is measured in absolute humidity.
[1 to 5 / / 1 /step]
1: LL (LL <= 4.3 g/m
3
)
2: ML (4.3 < ML <= 11.3 g/m
3
)
3: MM (11.3 < MM <= 18.0 g/m
3
)
4: MH (18.0 < MH <= 24.0 g/m
3
)
5: HH (24.0 g/m
3
< HH)