System Service Mode
SM Appendix 8-33 D023/D025
Appendix
SP Mode
Tables
002 Forced Setting *ENG
Selects the environmental condition
manually.
[0 to 5 / 0 / 1 /step]
0: The environmental condition is
determined automatically.
1: LL, 2: ML, 3: MM, 4: MH, 5: HH
003
Absolute Humidity:
Threshold 1
*ENG
Changes the humidity threshold
between LL and ML.
[0 to 100 / 4.3 / 0.01 g/m
3
/step]
004
Absolute Humidity:
Threshold 2
*ENG
Changes the humidity threshold
between ML and MM.
[0 to 100 / 11.3 / 0.01 g/m
3
/step]
005
Absolute Humidity:
Threshold 3
*ENG
Changes the humidity threshold
between MM and MH.
[0 to 100 / 18.0 / 0.01 g/m
3
/step]
006
Absolute Humidity:
Threshold 4
*ENG
Changes the humidity threshold
between MH and HH.
[0 to 100 / 24.0 / 0.01 g/m
3
/step]
007 Current Temp.: Display *ENG
Displays the current temperature.
[0 to 100 / 0 / 1 deg/step]
008
Current Relative Humidity:
Display
*ENG
Displays the current relative humidity.
[0 to 100 / 0 / 1%RH/step]
009
Current Absolute
Humidity: Display
*ENG
Displays the absolute humidity.
[0 to 100 / 0 / 0.01 g/m
3
/step]