Copier Installation
SM 2-15 D023/D025
Installation
Value Meaning Solution/ Workaround
5
Proxy error (Illegal user name or
password)
Check Proxy user name and password.
8 Other error
See "SP5816-208 Error Codes" below
this.
9
Request number confirmation
executing
Processing… Please wait.
8. Exit the SP mode.
SP5816-208 Error Codes
Cause Code Meaning Solution/ Workaround
-12002
Inquiry, registration attempted
without acquiring Request No.
Obtain a Request Number
before attempting the
Inquiry or Registration.
-12003 Attempted registration without
execution of a confirmation and
no previous registration.
Perform Confirmation
before attempting the
Registration.
-12004 Attempted setting with illegal
entries for certification and ID2.
Check ID2 of the
mainframe.
-12005 @Remote communication is
prohibited. The device has an
Embedded RC gate-related
problem.
Make sure that "Remote
Service" in User Tools is
set to "Do not prohibit".
-12006 A confirmation request was
made after the confirmation
had been already completed.
Execute registration.
Operation Error,
Incorrect Setting
-12007 The request number used at
registration was different from
the one used at confirmation.
Check Request No.

Table of Contents