System Service Mode
SM Appendix 8-141 D023/D025
Appendix
SP Mode
Tables
3013 [T Sensor Initial Set: Execution] Developer Initialization Setting
001 Execution: ALL -
002 Execution: COL -
003 Execution: Bk -
004 Execution: M -
005 Execution: C -
006 Execution: Y -
[0 or 1 / 0 / 1/step]
3014 [T Sensor Initial Set Result: Display] Developer Initialization Result: Display
Display: YCMK *ENG
[0 to 9999 / - / 1 /step ]
1: Success
2 to 9: Failure
001
Displays the developer initialization result. See the “Error Condition Tables” in
the Process Control Error section for details on the meaning of each code.
All colors are displayed. Values are displayed in the order Y C M Bk.
e.g., 1 (Y) 2 (C) 1 (M) 1 (Bk): Initialization of Cyan failed but the others
succeeded.
3015 [Forced Toner Supply: Execute] Forced Toner Supply ([Color])
001 Execution: ALL -
002 Execution: COL -
003 Execution: Bk -
004 Execution: M -
005 Execution: C -
006 Execution: Y -
[0 or 1 / 0 / 1 /step]
Executes the manual toner supply to the
development unit.