System Service Mode
D023/D025 8-142 SM Appendix
[Forced Toner Supply: Setting] Forced Toner Supply Setting ([Color])
3016
Specifies the manual toner supply time for each color.
001 Supply Time: Bk *ENG
002 Supply Time: M *ENG
003 Supply Time: C *ENG
004 Supply Time: Y *ENG
[0 to 30 / 4 / 1 sec/step]
[Vt Limit Error]
3020
DFU
001 Delta Vt Threshold *ENG
[0 to 5 / 5 / 0.01 V/step]
002 Upper Threshold *ENG
[0 to 5 / 4.7 / 0.01 V/step]
003
Threshold Number of
Upper counter
*ENG
[0 to 99 / 20 / 1 time/step]
004 Lower Threshold *ENG
[0 to 5 / 0.5 / 0.01 V/step]
005 Number of Lower counter *ENG
[0 to 99 / 10 / 1 times/step]
006 Upper Counter: Bk *ENG
007 Upper Counter: M *ENG
008 Upper Counter: C *ENG
009 Upper Counter: Y *ENG
010 Lower Counter: Bk *ENG
011 Lower Counter: M *ENG
012 Lower Counter: C *ENG
013 Lower Counter: Y *ENG
[0 to 99 / 0 / 1 times/step]