System Service Mode
SM Appendix 8-143 D023/D025
Appendix
SP Mode
Tables
[TD Sensor Initial Set] Developer Initialization Setting
3021
Specifies the developer agitation time for each color at the developer
initialization. DFU
001 Agitation Time: Bk *ENG
002 Agitation Time: M *ENG
003 Agitation Time: C *ENG
004 Agitation Time: Y *ENG
[0 to 200 / 30 / 1 sec/step]
005-008
Sets the execution flag of the developer initialization for each color. DFU
005 Execution Flag: Bk *ENG
006 Execution Flag: M *ENG
007 Execution Flag: C *ENG
008 Execution Flag: Y *ENG
[0 or 1 / 0 / 1/step]
0: Flag OFF, 1: Flag ON
This flag is cleared after executing TD
sensor initialization.
009 Prohibition *ENG
Enables or disables developer
initialization. DFU
[0 or 1 / 0 / 1/step]
0: Enable, 1: Disable