System Service Mode
D023/D025 8-144 SM Appendix
[Toner Replenishment Mode] DFU
3022
Specifies the toner supply time for each color in the toner supply mode.
001 Number: Bk *ENG
[0 to 30 / 8 / 1 sec/step]
002 Number: M *ENG
003 Number: C *ENG
004 Number: Y *ENG
[0 to 30 / 6 / 1 sec/step]
005-008 Sets the execution flag for the toner supply mode for each color.
005 Execution Flag: Bk *ENG
006 Execution Flag: M *ENG
007 Execution Flag: C *ENG
008 Execution Flag: Y *ENG
[0 or 1 / 0 / 1/step]
0: Flag OFF, 1: Flag ON
This flag is cleared after executing TD
sensor initialization.
3041 [Process Control Type]
Voltage Control *ENG
[0 or 1 / 1 / 1/step ] Alphanumeric
0: FIXED (Use the fixed values for the
charge DC bias and development DC bias
set with SP2-005 and SP2-229.)
1: CONTROL
001
Enables or disables potential control.
LD Power Control *ENG
[0 or 1 / 1 / 1/step] Alphanumeric
0: FIXED (at the value in SP2221-xxx)
1: CONTROL (adjusted by process control)
002
Selects the LD power control mode.