System Service Mode
SM Appendix 8-145 D023/D025
Appendix
SP Mode
Tables
Pre-ACC *ENG
[0 to 2 / 2 / 1/step]
0: Not Executed
1: Process Control
2: TC Control (TD Adjustment)
3: Not used
004
Selects the process control mode that is done before ACC.
3043 [TD Adjustment Mode]
Repeat Number: Power ON *ENG
[0 to 9 / 4 / 1 time/step]
001
Specifies the maximum number of repeats of the toner density adjustment at
power on.
0: Disabled, 1 to 3: Repeat number,
4: Repeat three times (No consumption mode)
5: Repeat three times (Toner is supplied only when the toner density is too low,
and toner is consumed only when the toner density is too dark.)
6 to 9: Disabled
Repeat Number: Initialization *ENG
[0 to 9 / 3 / 1 time/step]
002
Specifies the maximum number of repeats of the toner density adjustment at the
developer initialization.
0: Disabled, 1 to 3: Repeat number,
4: Repeat three times (No consumption mode)
5: Repeat three times (Toner is supplied only when the toner density is too low,
and toner is consumed only when the toner density is too dark.)
6 to 9: Disabled