System Service Mode
SM Appendix 8-169 D023/D025
Appendix
SP Mode
Tables
3361 [ID Sensor Sensitivity: Display] Not Used
001 K2K (Latest) *ENG
002 K5K (Latest) *ENG
003 K2M (Latest) *ENG
004 K5M (Latest) *ENG
005 K2C (Latest) *ENG
006 K5C (Latest) *ENG
007 K2Y (Latest) *ENG
008 K5Y (Latest) *ENG
[0 to 5 / - / 0.0001 /step]
3362 [ID Sensor Sensitivity: Setting] DFU
001 K2: Upper *ENG
[0 to 1 / 0.32 / 0.01 /step]
002 K2: Lower *ENG
[0 to 1 / 0.22 / 0.01 /step]
003 K5: Upper *ENG
[0 to 10 / 5 / 0.01 /step]
004 K5: Lower *ENG
[0 to 1 / 0.5 / 0.01 /step]
005 Kn: Lower *ENG
[0 to 1 / 0.1 / 0.01 /step]
006 Kn: Upper *ENG
[0 to 1 / 1 / 0.01 /step]
007 K5 Edit Point *ENG
[0 to 1 / 0.15 / 0.01 /step]
008 K5 Target Voltage *ENG
[0 to 5 / 1.63 / 0.01 V/step]
009 K5 Approximate Method *ENG
[0 to 1 / 1 / 1 /step]
0:Linear, 1: Curve
010
K2: Upper/Lower Limit
Coefficient 1
*ENG
[0 to 1 / 0 / 0.01 /step]