System Service Mode
D023/D025 8-182 SM Appendix
[Non-use Time Process Control Setting]
3531
Adjusts the threshold for the process control at stand-by.
When the current condition has changed by more than the values of these SPs
when compared with the conditions at the previous operation, the process
control at stand-by is executed.
001 Non-use Time Setting *ENG
[0 to 1440 / 360 / 1 minute/step]
002 Temperature Range *ENG
[0 to 99 / 10 / 1°C/step]
003 Relative Humidity Range *ENG
[0 to 99 / 50 / 1 %RH/step]
004 Absolute Humidity Range *ENG
[0 to 99 / 6 / 1 g/m
3
/step]
005
Maximum Execution
Number
*ENG
Adjusts the maximum execution time for
the process control at stand-by.
[0 to 99 / 10 / 1 time/step]
3611 [Development Gamma: Display/Set]
001 Bk (Current) *ENG
002 M (Current) *ENG
003 C (Current) *ENG
004 Y (Current) *ENG
Displays the current development
gamma for each color.
[0 to 5 / - / 0.01 mg/cm
2
/kV /step]
005 Bk (Target Display) *ENG
006 M (Target Display) *ENG
Displays the target development gamma
for each color.
[0 to 5 / 0.85 / 0.01 mg/cm
2
/kV /step]
007 C (Target Display) *ENG
[0 to 5 / 0.8 / 0.01 mg/cm
2
/kV /step]
008 Y (Target Display) *ENG
[0 to 5 / 0.77 / 0.01 mg/cm
2
/kV /step]