SERVICE PROGRAM MODE
G108 5-36 SM
5.1.4 MEMORY CLEAR/COUNTER CLEAR
The table lists the data and information cleared or deleted by the following SPs:
1) Engine SP5-801 (Memory Clear)
2) Engine SP5-998 (Engine Memory Clear)
3) Engine SP7-808 (Counter Clear)
The serial number information, meter charge setting (Engine SP5-930), and meter
charge counters (Engine SP8-58x) are not cleared.
NOTE: In this section (5.1.4), the letter “x” represents a whole number from “0” to
“9.”
Service Program Cleared or Deleted
5801 003 Memory Clear > SCS Engine SP5-833
Engine SP7-401, 403, 502, 504, 506, and 507
Engine SP8-00x, 02x, 03x, 06x, 07x, 42x, 43x, 44x, 451,
46x, 471, 48x, 51x, 52x, 771, 781, 801, 831,
841, 851, 861, 871, 881, 891, 901, 941
5801 004 Memory Clear > IMH No SP modes are cleared. All files stored in the HDD are
deleted.
5801 005 Memory Clear > MCS No SP modes are cleared.
5801 008 Memory Clear > PRT Service settings:
• Bit switches
• Gamma settings (User & Service)
• Toner Limit
User settings:
• Tray Priority
• Menu Protect
• System Setting except for setting of Energy Saver
• I/F Setup (I/O Buffer and I/O Timeout)
• PCL Menu
5801 011 Memory Clear > NCS All setting of network setup
5998 Engine Memory Clear When the NVRAM error (SC660) does not occur, the SP
deletes the following data:
• Total Page Data • Duplex Total Page Data
• Each Image Data • Next Life Limit Data
• Life Period Data
When the NVRAM error (SC660) occurs, the SP deletes
the following data:
• Total Page Data • Duplex Total Page Data
• Each Image Data • Next Life Limit Data
• Life Period Data • ID Data
• Margin for Top • Margin for Left
• Margin for Left 1 • Margin for Left 3
• All Tune-Up Data (including Laser Power Default,
Developer Bias Voltage Default, THV, THV2, CBV, FBV,
TM1 and TM2).
7808 001 Counter Clear SP7-401, 403, 502, 504, 506, 507
SP8-00x, 02x, 03x, 06x, 07x, 42x, 43x, 44x, 451, 46x, 471,
48x, 51x, 52x, 771, 781, 801, 831, 841, 851, 861,
871, 881, 891, 901, 941