6. Do a RAM clear for the controller settings:
•
SCS (SP5-801-003): System settings
•
PRT (SP5-801-008): Printer settings
•
NCS (SP5-801-011): System default and I/F settings
7. Do a Counter Clear (SP7-808).
8. Do these settings:
•
Meter Charge Mode (SP5-930-001)
•
Counter Method (SP5-045)
•
Telephone Number Setting (SP5-812)
NOTE: These are related to service contracts.
9. For any SP Mode that was changed from its original design default or factory
default, input the most recent value.
Refer to the SMC Report (Printed in step 1) for the most recent values.
3.10.2 INPUT OUTPUT DEVICE PCB
1. Top cover ( 3.1.1)
2. IOD cover [A] ( x 5)
3. Input output device [B] (Flat cable x 2, All 's, x 6)
Reassembling
Make sure that the left end of the IOD cover is under the top end of the BCU cover
when you reassemble.
G108R907.WMF
[A]
[B]
⇒